Film CMM
Coordinate measurement planning, simulation and reporting — the inspection-side companion to Thin Film Physics. Build the part from nominal features, align it 3-2-1 on its datums, run a simulated probe measurement, and get fitted results, GD&T checks and a printable inspection report.
$498.99 one-time · Maintenance Plan $99.99/mo — a separate support plan on top of the software: software updates and custom filter designs to your specifications while you're on the plan. One custom design to your spec without the plan: $500. We maintain the software and provide updates. Or all six tools together — the Complete Package: $999.99 one-time opening price (the package price doubles to $1,999.98 after Dec 25, 2026), plus the Maintenance Plan at $99.99/mo — email to order.
—
Features in the routine
—
Characteristics checked
—
Characteristics in tolerance
—
Out of tolerance

Part, Alignment & Probe

Film CMM works the way a real inspection routine works: the part is aligned 3-2-1 before anything is reported. Datum A (base plane) levels the part and sets the Z axis · Datum B (edge line) clocks it — rotation about Z · Datum C (corner point) sets the origin. Every position result below is reported in that datum reference frame, A | B | C. The simulated part sits slightly misaligned on the machine, exactly like a real setup — the alignment is what brings the numbers home.

Hit coordinates in the probe path are probe-ball centre points. Fits compensate the tip radius — added back for internal features (bores), subtracted for external features (boss, sphere) — so reported diameters are true surface diameters. Change the tip diameter and the fits re-compensate without re-measuring.

Honesty line: simulated probe data for planning, training, and report layout — not a live machine connection. Film CMM is an offline programming and evaluation station: build routines here, export them as standard DMIS programs for your CMM's software, and import measured point data back for evaluation. Film CMM does not connect directly to a machine controller.

Routine — Feature Tree

Click a feature to see its probe path and hit coordinates. ● = last run's verdict per feature.

Graphical View — Top View (X–Y)

Plate outline with nominal features in blue, fitted features in green (in tolerance) or red (out of tolerance). Small dots are probe hits as the run progresses; the ring is the probe tip travelling feature to feature. Datum markers: A base plane, B edge line, C origin corner.

Features — Nominal Definitions

Nominal geometry and tolerances, entered in millimetres. Size tolerance is ± on diameter; Form is the GD&T form callout for the type (flatness / straightness / circularity / cylindricity); Position is a diametral true-position tolerance (Ø) against datums A | B | C. New planes get a 60 × 40 mm hit pattern, new lines run 80 mm along X, new cylinders stand 12 mm tall. Edit a value and the next run uses it.

NameTypeXYZØ (mm)± SizeFormØ Pos

Probe Path — —

Select a feature in the tree to see the hits taken on it.

HitXYZNote

Machine Compatibility — DMIS Programs & Measured Data

Film CMM is an offline programming and evaluation station: build routines here, export them as standard DMIS programs for your CMM's software, and import measured point data back for evaluation. Film CMM does not connect directly to a machine controller. The export follows the published DMIS (Dimensional Measuring Interface Standard) statement formats — the neutral program format CMM software that reads DMIS can import. It is not certified against any specific machine or software package.

No measured data imported — every feature is currently evaluated on simulated probe data.

The same 3-2-1 alignment is applied to imported points before fitting, so export your points in machine coordinates. A feature needs a minimum number of hits to fit (plane 3 · line 2 · point 1 · circle 3 · cylinder 6 · sphere 4); below that it stays on simulated data. Features evaluated on imported hits are marked MEASURED DATA in the tree and the report; the rest are marked SIMULATED.

Inspection Report — Film CMM
Film CMM — Inspection Report
Part—Date—
Units—Alignment3-2-1 · Datum reference frame A | B | C
Probe—Verdict—
FeatureCharacteristicNominalMeasuredDeviationToleranceResult

Deviations for position are the diametral true-position value (Ø) unless noted. Form values (flatness, circularity, cylindricity, straightness, perpendicularity) are total zone widths. All results come from least-squares fits of the simulated probe hits, in the A | B | C datum reference frame.